Viper Fang 28T Spécifications Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
to overflow during charging due to expansion.
Replace the caps prior to charging.
5. Plug approved charger into grounded wall
outlet before plugging the charger into the
machine.
6. Plug charger into red charger receptacle
located in the front left of the battery
7. compartment.
8. Flip up the recovery tank “kick stand” and
gently lay the recovery tank down until it rests
on the stand.
9. The charger will automatically begin to
charger the batteries, and it will automatically
shut down once the batteries are fully charged.
10. Upon completion of charging, first unplug the
charger from the wall outlet, and then
disconnect the charger from the machine.
11. Check the battery level after charging is
complete. If fluid level is low, add distilled
water to bring the fluid level up to the bottom
of the sight tubes. Replace the caps and wipe
the batteries down with a towel.
PREVENTATIVE MAINTENANCE
: Before performing any maintenance on
the machine, be sure that the power is turned off,
or the batteries are disconnected!
: Repairs are to be completed by
Authorized Service Centers only. Any repairs
completed by unauthorized persons will void the
warranty.
DAILY MAINTENANCE
1. Remove pad driver / brush and clean with
approved cleaner.
2. Drain recovery and solution tanks completely
and rinse out with clean water. Visually check
the recovery tank for debris and clean out as
necessary.
3. Raise squeegee assembly off floor and wipe it
down with a damp towel. Be sure to store the
squeegee in the up position.
4. Remove the float shut-off assembly and rinse
it out with clean water.
5. Clean machine with an approved cleaner and a
damp towel.
6. Recharge batteries.
WEEKLY MAINTENANCE
1. Check fluid level in batteries.
2. Check batteries for loose or corroded cables.
3. Keep battery tops clean from corrosion.
MONTHLY MAINTENANCE
1. Check machine for leaks and loose fasteners.
2. Lubricate all grease points and pivot points
with silicon spray and approved grease.
3. Place machine over a floor drain. Flush
solution system by pouring 3 gallons of hot
water and approved alkaline detergent into the
solution tank and running machine (with
solution control on) for 45 seconds. Turn
machine off and let it sit overnight. Then next
day, drain the remaining solution and rinse the
solution tank out with clean water.
VACUUM MOTOR MAINTENANCE